Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Journal of Experimental Hematology ; (6): 653-658, 2022.
Article in Chinese | WPRIM | ID: wpr-939672

ABSTRACT

OBJECTIVE@#To establish the droplet digital PCR (ddPCR) assay for the detection of NPM1 type A mutation in patients with acute myeloid leukemia (AML), and to evaluate its specificity, sensitivity and its value in clinical application.@*METHODS@#NPM1 mutant and wildtype plasmids were used to verify the performance of ddPCR. Both ddPCR and Sanger sequencing were used to detect the bone marrow samples of 87 AML patients, which were confirmed by next generation sequencing (NGS). Moreover, NPM1 mutation burden was dynamically monitored in five patients by ddPCR.@*RESULTS@#The limit of blank (LOB) of ddPCR established for NPM1 mutation detection was 1.1 copies/μl, and the limit of detection (LOD) was 2.43 copies/μl, which had good linearity. Among the 87 newly diagnosed AML patients, ddPCR identified seventeen cases positive for NPM1 mutation (19.5%), which was consistent with Sanger sequencing. NGS confirmed 12 positive cases, including 8 of type A mutations, 2 of type D mutations, and 2 of rare type mutations. The results of dynamic monitoring of NPM1 mutation burden in 5 patients showed that the NPM1 mutation burden decreased obviously even close to 0, when patients achieve complete remission after chemotherapy. However, the mutation burden was increased again at the time of relapse.@*CONCLUSION@#In this study, we established a ddPCR method for detection of NPM1 mutation with good sensitivity and repeatability, which can be used for screening NPM1 mutation in newly diagnosed AML patients and for minimal residual disease monitoring after remission in positive AML patients to guide treatment.


Subject(s)
Humans , Leukemia, Myeloid, Acute/therapy , Mutation , Nuclear Proteins/genetics , Nucleophosmin , Polymerase Chain Reaction , Prognosis
2.
Chinese Journal of Stomatology ; (12): 245-247, 2011.
Article in Chinese | WPRIM | ID: wpr-339762

ABSTRACT

<p><b>OBJECTIVE</b>To analyze the amount and tendency of methyl methacrylate (MMA) released from autopolymerized denture base polymer (self-curing resin) during processing using time-of-flight mass spectrometer (TOF-MS).</p><p><b>METHODS</b>Self-curing resin was mixed in the container using a ratio of 2 g of powder to 1 g of liquid in accordance with the manufacturer's instructions for 40 s as a specimen. The amount of MMA released from the specimen was continuously monitored and simultaneously recorded every minute by TOF-MS since immediately after mixing. A total of five specimens were monitored.</p><p><b>RESULTS</b>The amount of MMA increased dramatically at 11 min [(45.2 ± 3.5) mg/L] after mixing, and reached the highest level at 13 min [(228.9 ± 22.6) mg/L], then become stable at 23 min [(8.8 ± 2.3) mg/L] after mixing.</p><p><b>CONCLUSIONS</b>The releasing tendency of MMA could be analyzed accurately with continuously monitoring during processing. The amount of MMA released from self-curing resin changed rapidly and the processing was complicated and changeful.</p>


Subject(s)
Denture Bases , Mass Spectrometry , Methods , Materials Testing , Methylmethacrylate , Chemistry , Polymers , Chemistry
SELECTION OF CITATIONS
SEARCH DETAIL